Graco 3A0868G Power Roller User Manual


 
Display Module
24 3A0868G
Ranges for User Inputs
This table is a one-sheet reference of the data range/options accepted for each user input and the default setting.
See the page indicated in the table for further screen information, if needed.
* The system will attempt to hold whatever accuracy is entered. For some ratios and applications, testing shows that actual sys-
tem accuracy may be ±2% or ±5%. See Technical Data, page 73.
Page Screen User Input Range/Options Default
39 Run Mix Batch (3)
Target Volume
1 to 9999 cc 0 cc
40 Run Job Number (38)
User Number
000000000 to 999999999 000000000
42 Password (16)
Password
0000 to 9999 0000 (disabled)
43 Configure 1 (18)
System Type
Meters; 50cc Pump; 75cc Pump; 100cc Pump;
125cc Pump; 150cc Pump
Meters
43 Configure 1 (18)
Gun Flush Box Enable
On or Off Off
43 Configure 1 (18)
Number of Guns
1 or 2 guns 1 gun
43 Configure 2 (19)
Gun 1 or Gun 2 hose length
0.1 to 45.7 m / 0.3 to 150 ft 1.53 m / 5.01 ft
43 Configure 2 (19)
Gun 1 or Gun 2 hose diameter
0.1 to 1 inch 0.25 inches
43 Configure 2 (19)
Flow Rate Region
High (250 cc/min or higher) or
Low (<250 cc/min)
High
43 Configure 2 (19)
Air Flow Switch
On or Off On
44 Configure 3 (20)
USB Log Language
Chinese; Dutch; English; French; German; Ital-
ian; Japanese; Korean; Portuguese;
Russian; Spanish; Swedish;
English
44 Configure 3 (20)
Date Format
mm/dd/yy;
dd/mm/yy;
yy/mm/dd
mm/dd/yy
44 Configure 3 (20)
Date
01/01/00 to 12/31/99 Set at factory
44 Configure 3 (20)
Time
00:00 to 23:59 Set at factory
44 Configure 3 (20)
Password
0000 to 9999 0000 (disabled)
44 Configure 3 (20)
Backlight Timer
0 to 99 minutes 0 minutes
44 Configure 4 (21)
Distance Units
Feet/inches or Meters/cm Feet/inches
44 Configure 4 (21)
Volume Units
Liters; Gallons US; Gallons Imperial Gallons US
44 Configure 4 (21)
Pressure Units
psi; Bar; MPA psi
44 Recipe 1-1 (28)
Ratio
0:1 to 30:1
Note: Enter 0 to dispense A only.
1:1
44 Recipe 1-1 (28)
Ratio Tolerance
1 to 99 percent* 5 percent
44 Recipe 1-1 (28)
Potlife Timer
0 to 240 minutes
Note: If set to 0, potlife alarm is disabled.
60 minutes
44 Recipe 1-2 (29)
Flush Times- First (A purge),
Second (B purge), or Third
(using A or B, chosen by user)
0 to 240 seconds
Note: If set to 0, the valve(s) will not flush.
60 seconds
45 Maintenance 1 (24)
Pump A or Pump B
0 to 9,999,999 0
45 Maintenance 1 (24)
Solvent Valve A or Solvent
Valve B
0 to 9,999,999 0
45 Maintenance 2 (25)
Dose Valve A or Dose Valve B
0 to 9,999,999 0
45 Maintenance 3 (26)
Fluid Filter A or B, or Air Filter
0 to 9999 days 0 days
46 Calibration 1 (22)
Pump A or Pump B Factor
5 to 50 cc/in 50cc: 10 cc/in.
75cc: 15 cc/in.
100 cc: 20 cc/in.
125cc: 25 cc/in.
150cc: 30 cc/in.
46 Calibration 2 (23)
Actual Dispensed Volume
1 to 9999 cc 0 cc