Hitachi SJ700-2 Series Welding System User Manual


 
1 - 14
Default
Code Function name Monitored data or setting
_FF _FEF _FUF
Note
H001 Auto-tuning Setting
00 (disabling auto-tuning), 01 (auto-tuning without rotation), 02 (auto-tuning
with rotation)
00
H002 Motor data selection, 1st motor
00 (Hitachi standard data), 01 (auto-tuned data),
02 (auto-tuned data [with online auto-tuning function])
00
H202 Motor data selection, 2nd motor
00 (Hitachi standard data), 01 (auto-tuned data),
02 (auto-tuned data [with online auto-tuning function])
00
H003 Motor capacity, 1st motor 0.20 to 75.00 (kW) Factory setting
H203 Motor capacity, 2nd motor 0.20 to 75.00 (kW) Factory setting
H004 Motor poles setting, 1st motor 2, 4, 6, 8, 10 (poles) 4
H204 Motor poles setting, 2nd motor 2, 4, 6, 8, 10 (poles) 4
H005 Motor speed constant, 1st motor 0.001 to 9.999, 10.00 to 80.00 (10.000 to 80.000) 1.590
H205 Motor speed constant, 2nd motor 0.001 to 9.999, 10.00 to 80.00 (10.000 to 80.000) 1.590
H006
Motor stabilization constant, 1st
motor
0. to 255. 100.
H206
Motor stabilization constant, 2nd
motor
0. to 255. 100.
H306
Motor stabilization constant, 3rd
motor
0. to 255. 100.
H020 Motor constant R1, 1st motor
0.001 to 9.999, 10.00 to 65.53 ()
Depending on motor capacity
H220 Motor constant R1, 2nd motor
0.001 to 9.999, 10.00 to 65.53 ()
Depending on motor capacity
H221 Motor constant R2, 1st motor
0.001 to 9.999, 10.00 to 65.53 ()
Depending on motor capacity
H221 Motor constant R2, 2nd motor
0.001 to 9.999, 10.00 to 65.53 ()
Depending on motor capacity
H222 Motor constant L, 1st motor 0.01 to 99.99, 100.0 to 655.3 (mH) Depending on motor capacity
H222 Motor constant L, 2nd motor 0.01 to 99.99, 100.0 to 655.3 (mH) Depending on motor capacity
H223 Motor constant Io 0.01 to 99.99, 100.0 to 655.3 (A) Depending on motor capacity
H223 Motor constant Io, 2nd motor 0.01 to 99.99, 100.0 to 655.3 (A) Depending on motor capacity
H224 Motor constant J 0.001 to 9.999, 10.00 to 99.99, 100.0 to 999.9, 1000. to 9999. Depending on motor capacity
H224 Motor constant J, 2nd motor 0.001 to 9.999, 10.00 to 99.99, 100.0 to 999.9, 1000. to 9999. Depending on motor capacity
H030 Auto constant R1, 1st motor
0.001 to 9.999, 10.00 to 65.53 ()
Depending on motor capacity
H230 Auto constant R1, 2nd motor
0.001 to 9.999, 10.00 to 65.53 ()
Depending on motor capacity
H231 Auto constant R2, 1st motor
0.001 to 9.999, 10.00 to 65.53 ()
Depending on motor capacity
H231 Auto constant R2, 2nd motor
0.001 to 9.999, 10.00 to 65.53 ()
Depending on motor capacity
H232 Auto constant L, 1st motor 0.01 to 99.99, 100.0 to 655.3 (mH) Depending on motor capacity
H232 Auto constant L, 2nd motor 0.01 to 99.99, 100.0 to 655.3 (mH) Depending on motor capacity
H233 Auto constant Io, 1st motor 0.01 to 99.99, 100.0 to 655.3 (A) Depending on motor capacity
H233 Auto constant Io, 2nd motor 0.01 to 99.99, 100.0 to 655.3 (A) Depending on motor capacity
H234 Auto constant J, 1st motor 0.001 to 9.999, 10.00 to 99.99, 100.0 to 999.9, 1000. to 9999. Depending on motor capacity
Control constants
H234 Auto constant J, 2nd motor 0.001 to 9.999, 10.00 to 99.99, 100.0 to 999.9, 1000. to 9999. Depending on motor capacity