Hitachi SJ700-2 Series Welding System User Manual


 
1 - 3
Code Function name Monitored data or setting Default Note
d025 User monitor 0 -2147483647 to 2147483647 (upper 4 digits including “-“)
d026 User monitor 1 -2147483647 to 2147483647 (upper 4 digits including “-“)
d027 User monitor 2 -2147483647 to 2147483647 (upper 4 digits including “-“)
d028 Pulse counter 0 to 2147483647 (upper 4 digits)
d029 Position setting monitor -1073741823 to 1073741823 (upper 4 digits including “-“)
d030 Position feedback monitor -1073741823 to 1073741823 (upper 4 digits including “-“)
d080 Trip Counter 0. to 9999., 1000 to 6553 (10000 to 65530) (times)
d081
Trip monitoring 1 Factor, frequency (Hz), current (A), voltage across P-N (V), running time (hours),
power-on time (hours)
d082
Trip monitoring 2 Factor, frequency (Hz), current (A), voltage across P-N (V), running time (hours),
power-on time (hours)
d083
Trip monitoring 3 Factor, frequency (Hz), current (A), voltage across P-N (V), running time (hours),
power-on time (hours)
d084
Trip monitoring 4 Factor, frequency (Hz), current (A), voltage across P-N (V), running time (hours),
power-on time (hours)
d085
Trip monitoring 5 Factor, frequency (Hz), current (A), voltage across P-N (V), running time (hours),
power-on time (hours)
d086
Trip monitoring 6 Factor, frequency (Hz), current (A), voltage across P-N (V), running time (hours),
power-on time (hours)
d090 Programming error monitoring Warning code
d102 DC voltage monitoring 0.0 to 999.9 (V)
d103 BRD load factor monitoring 0.0 to 100.0 (%)
d104 Electronic thermal overload monitoring 0.0 to 100.0 (%)
1.2.2 Function Mode
Default
Code Function name Monitored data or setting
_FF _FEF _FUF
F001
Output frequency setting 0.0, "start frequency" to "maximum frequency" (or maximum frequency,
2nd/3rd motors) (Hz)
0.0 to 100.0 (when PID function is enabled)
0.00
F002 Acceleration (1) time setting 0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s) 30.00
F202 Acceleration (1) time setting, 2nd
motor
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s) 30.00
F302 Acceleration (1) time setting, 3rd
motor
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s) 30.00
F003 Deceleration (1) time setting 0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s) 30.00
F203 Deceleration time setting, 2nd motor 0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s) 30.00
F303 Deceleration time setting, 3rd motor 0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s) 30.00
F004 Keypad Run key routing 00 (forward rotation), 01 (reverse rotation) 00