Hitachi SJ700-2 Series Welding System User Manual


 
1 - 4
1.2.3 Extended Function Mode
Default
Code Function name Monitored data or setting
_FF _FEF _FUF
Note
A001
Frequency source setting 00 (keypad potentiometer) (*1), 01 (control circuit terminal block), 02 (digital
operator), 03 (RS485), 04 (option 1), 05 (option 2), 06 (pulse-string input), 07
(easy sequence), 10 (operation function result)
02 01 01
A002
Run command source setting 01 (control circuit terminal block), 02 (digital operator), 03 (RS485), 04 (option
1), 05 (option 2)
02 01 01
A003 Base frequency setting 30. to "maximum frequency " (Hz) 60. 50. 60.
A203
Base frequency setting, 2nd
motor
30. to "maximum frequency, 2nd motor" (Hz)
60. 50. 60.
A303
Base frequency setting, 3rd
motor
30. to "maximum frequency, 3rd motor" (Hz)
60. 50. 60.
A004 Maximum frequency setting 30. to 400. (Hz) 60. 50. 60.
A204
Maximum frequency setting, 2nd
motor
30. to 400. (Hz)
60. 50. 60.
Basic settings
A304
Maximum frequency setting, 3rd
motor
30. to 400. (Hz)
60. 50. 60.
A005
[AT] selection 00 (switching between O and OI terminals), 01 (switching between O and O2
terminals), 02 (switching between O terminal and keypad potentiometer) (*1),
03 (switching between OI terminal and keypad potentiometer) (*1), 04
(switching between O2 and keypad potentiometer) (*1)
00
A006
[O2] selection 00 (single), 01 (auxiliary frequency input via O and OI terminals)
(nonreversible), 02 (auxiliary frequency input via O and OI terminals)
(reversible), 03 (disabling O2 terminal)
03
A011
[O]-[L] input active range start
frequency
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.00
A012
[O]-[L] input active range end
frequency
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.00
A013
[O]-[L] input active range start
voltage
0. to "[O]-[L] input active range end voltage" (%)
0.
A014
[O]-[L] input active range end
voltage
"[O]-[L] input active range start voltage" to 100. (%)
100.
A015
[O]-[L] input active range start
frequency selection
00 (external start frequency), 01 (0 Hz)
01
A016
External frequency filter time
const.
1. to 30. or 31. (500 ms filter ±0.1 Hz with hysteresis)
31.
Analog input and others
A017
Easy sequence function
selection
00 (disabling), 01 (enabling)
00
A019
Multispeed operation selection 00 (binary: 16 speeds selectable with 4 terminals), 01 (bit: 8 speeds selectable
with 7 terminals)
00
A020 Multispeed frequency setting 0.0 or “start frequency” to “maximum frequency” (Hz) 0.00
A220
Multispeed frequency setting,
2nd motor
0.0 or “start frequency” to “maximum frequency, 2nd motor” (Hz)
0.00
A320
Multispeed frequency setting,
3rd motor
0.0 or “start frequency” to “maximum frequency, 3rd motor” (Hz)
0.00
A021 Multispeed 1 setting 0.0 or “start frequency” to “1st maximum frequency” (Hz) 0.00
A022 Multispeed 2 setting 0.0 or “start frequency” to “2nd maximum frequency” (Hz) 0.00
A023 Multispeed 3 setting 0.0 or “start frequency” to “3rd maximum frequency” (Hz) 0.00
A024 Multispeed 4 setting 0.0 or “start frequency” to “n-th maximum frequency” (Hz) 0.00
A025 Multispeed 5 setting 0.0 or “start frequency” to “n-th maximum frequency” (Hz) 0.00
A026 Multispeed 6 setting 0.0 or “start frequency” to “n-th maximum frequency” (Hz) 0.00
A027 Multispeed 7 setting 0.0 or “start frequency” to “n-th maximum frequency” (Hz) 0.00
A028 Multispeed 8 setting 0.0 or “start frequency” to “n-th maximum frequency” (Hz) 0.00
A029 Multispeed 9 setting 0.0 or “start frequency” to “n-th maximum frequency” (Hz) 0.00
A030 Multispeed 10 setting 0.0 or “start frequency” to “n-th maximum frequency” (Hz) 0.00
A031 Multispeed 11 setting 0.0 or “start frequency” to “n-th maximum frequency” (Hz) 0.00
A032 Multispeed 12 setting 0.0 or “start frequency” to “n-th maximum frequency” (Hz) 0.00
A033 Multispeed 13 setting 0.0 or “start frequency” to “n-th maximum frequency” (Hz) 0.00
A034 Multispeed 14 setting 0.0 or “start frequency” to “n-th maximum frequency” (Hz) 0.00
A035 Multispeed 15 setting 0.0 or “start frequency” to “n-th maximum frequency” (Hz) 0.00
A038 Jog frequency setting "Start frequency" to 9.99 (Hz) 1.00
Multispeed operation and jogging
A039 Jog stop mode
00 (free-running after jogging stops [disabled during operation]), 01
(deceleration and stop after jogging stops [disabled during operation]), 02 (DC
braking after jogging stops [disabled during operation]), 03 (free-running after
jogging stops [enabled during operation]), 04 (deceleration and stop after
jogging stops [enabled during operation]), 05 (DC braking after jogging stops
[enabled during operation])
00
.