See “Diagnosing problems using Light Path Diagnostics” on page 65 for information on what
action to take if there is a component error.
Table 3. SW4 Light Path Diagnostics LED locations
LED error Action
NMI Ceck the error log for additional information. Reboot the blade
server. If the error still exists, replace the system board.
MIS Check the processors to make sure they are at the same
speed.
SBRD Reboot the blade server. If the error still exists, replace the
system board.
TEMP Check the SBCE unit blowers and air inlets. Check the room
temperature.
Light Path Diagnostics LED Check the Light Path Diagnostics LED for errors
Ligh Path Diagnostics button (SW4) Press SW4 to locate faults on the system board. If the
processor or memory LED is lit, reseat the component. If the
LED remains lit, replace the defective component.