Service processor problems
Light path diagnostics
If the system-error LED on the system LED panel on the front or rear of the SBCE unit is lit, one or
more error LEDs on the SBCE unit components might also be lit. These LEDs help identify the
cause of the problem.
Diagnosing problems using Light Path Diagnostics
This section provides the information about using the Light Path Diagnostics to diagnose problems
that might arise during installation. To locate the actual component that caused the error, you must
locate the lit error LED on that component.
The following steps illustrate how to use the Light Path Diagnostics to diagnose a system error:
1. Shut down the operating system, turn off the blade server, and remove the blade server from the
SBCE unit.
2. Place the blade server on a flat, non-conductive surface.
3. Remove the cover from the blade server.
4. Press and hold the Light Path Diagnostics button to relight the LEDs that were lit before you
removed the blade server from the SBCE unit. The LEDs will remain lit for as long as you press
the button, to a maximum of 25 seconds.
See ’Understanding the control panel and LEDs’ on page 13 for information about the control panel
buttons and error LEDs. See ’Using Light Path Diagnostics to troubleshoot the system board’ on
page 17 See Figure 6 on page 17 for the location of the Light Path Diagnostics button and error
LEDs, then see Table 7 on page 67 for a description of the settings.
Light Path Diagnostics LEDs
The following table lists the LEDs on the Light Path Diagnostics panel, the problems they indicate,
and actions to take to solve the problems. The following illustration is the Light Path Diagnostics
key located on the system board. See Figure 6 on page 17 for more information about locating the
Light Path Diagnostics LEDs.
Symptom Suggested action
The service processor
reports a general monitor
failure.
Shut down the operating system and turn off the blade server; then remove the
blade server from the SBCE unit, wait for 30 seconds, reinstall the blade server
in the SBCE unit, and restart the blade server.