F-9
TROUBLESHOOTING & REPAIR
SCOPE SETTINGS
This is the typical output voltage waveform generated
from a properly operating machine. Note that each
vertical division represents 10 volts and that each hor-
izontal division represents 20 milliseconds in time.
Note: Scope probes connected at machine output ter-
minals. Positive probe to (+) terminal, negative probe
to (–) terminal.
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM
0
volts
10 volts/Div 20 ms/Div
C1
Volts/Div ........................................................10/Div
Horizontal Sweep.....................................20 ms/Div
Coupling .............................................................DC
Trigger..........................................................Internal