Lincoln Electric SP-100 Welder User Manual


 
A-1
INSTALLATION
SP-100
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
Fuse or
Output Mode Input Voltage Breaker Size Input Amps Power Cord Extension Cord
RATED 115V/60Hz 20 Amp 20 15 Amp, 125V, Three Conductor
Three Prong Plug #14 AWG
(NEMA Type 5-15P) (2.1 mm
2
) or Larger
For lengths up to
MAXIMUM 115V/60Hz 25 Amp 25 25 Amp, 125V, 25 Ft. (7.5 m)
Three Prong Plug
(NEMA Type 5-20P) Three Conductor
#12 AWG
CSA 115V/60Hz 15 Amp 12 15 Amp, 125V, (3.3 mm
2
)
Three Prong Plug For lengths up to
(NEMA Type 5-15P) 50 Ft. (15 m)
TECHNICAL SPECIFICATIONS – SP-100
INPUT – SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
RECOMMENDED INPUT CABLE AND FUSE SIZES
Height Width Depth Weight
12.0 in 9.75 in 16.5 in 54 Ibs
305 mm 248 mm 419 mm 24.3 kg
PHYSICAL DIMENSIONS
Standard Voltage/Frequency Input Current
115V/60Hz 20 Amps - Rated Output
115V/60Hz 25 Amps - Maximum Output
115V/60Hz 12 Amps - CSA Rated output
Duty Cycle Amps Volts at Rated Amperes
20% Duty Cycle 90 18
30% Duty Cycle 100 17
20% Duty Cycle - CSA Rated Output 63 20
Welding Current Range (Continuous) Maximum Open Circuit Voltage Auxiliary Power
Rated DC Output: 0 - 90 amps 28 N/A
Maximum DC Output: 0 - 100 amps
CSA Rated DC Output: 0 - 63 amps