Lincoln Electric SVM132-A Welder User Manual


 
E-4
THEORY OF OPERATION
E-4
VARIABLE VOLTAGE
BOARD, METER SHUNT,
WIRE SPEED AND
REMOTE OUTPUT
CONTROLS
The optional variable voltage board
enables the LN-8 to be used with a con-
stant current power source. The vari-
able voltage board monitors the arc
voltage via leads #21 and #567 and
modifies the wire feed speed according
to arc voltage variations and require-
ments.
The wire speed control dictates to the
control board the directives of the
operator. The control board adjusts the
armature voltage applied to the wire
feed motor to change the motor speed.
The remote output control permits
power source control from the LN-8
unit. The remote control is coupled to
the welding power source via leads #75,
#76, and #77 through the input
receptacle.
The electrode meter shunt, which is
connected to and also in series with the
gun connector block, senses the weld-
ing current and arc voltage. This infor-
mation is used by the variable voltage
board and also the optional meter kit.
FIGURE E.3 – VARIABLE VOLTAGE BOARD, METER SHUNT, WIRE SPEED,
AND REMOTE OUTPUT CONTROLS
LN-8
REMOTE
OUTPUT
CONTROL
ELECTRODE
METER
SHUNT
WIRE
FEED
MOTOR
CIRCUIT
BREAKER
INPUT
RECEPTACLE
VARIABLE VOLTAGE
BOARD
CONTROL
BOARD
WIRE FEED
SPEED CONTROL
THERMAL
CIRCUIT
BREAKER
RELAY
BOARD
GLP
REED
SWITCH
TRIGGER
TRANS.
WIRE
FEED
SWITCH
INTERLOCK
SWITCH
FUSE
GUN
CABLE
RECEPTACLE
FIELD
ARMATURE
#3
2
A
OPTIONAL
BURNBACK
BOARD
CONTROL
#2
&
#4
C
O
N
T
A
C
T
O
R
#531
#31
2 OHMS
#32 #32A
#75
#76
#77
#21
#567
NOTE: Unshaded areas of block logic diagrams are the subject of discussion.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC