F-11
TROUBLESHOOTING AND REPAIR
F-11
FIGURE F.1 – LN-8 ELECTRICAL SEQUENCE OF OPERATION (continued)
LN-8
DE-ENERGIZES
2 CR
REED SWITCH
OPENS INTERLOCK
ON 1 CR (NOTE 2)
OPENS 531-7
DE-ENERGIZES 1 CR
OPENS 683-32A CIRCUIT
CLOSES 682-683
REVERSES
MOTOR FIELD
WELDING
ELECTRODE IS
COLD TO WORK
RELEASE
GUN TRIGGER
OPENS 2-8 (NOTE 1)
OPENS 2-4 CIRCUIT
DE-ENERGIZES
POWER SOURCE
CONTACTOR
BREAK
WELDING ARC
DE-ENERGIZES
POWER SOURCE
PILOT RELAY
DISCONNECTS MOTOR ARMATURE
AND CONTROL CIRCUIT FROM
INPUT AC LINE - (DE-ENERGIZES
AUX. EQUIPMENT IF CONNECTED)
3CR (NOTE 3)
REED SWITCH
MOMENTARILY
CLOSES
DYNAMIC BRAKE
CURRENT FLOWS
THROUGH FREE
WHEELING DIODE (D-7 ON
CONTROL BOARD)
DISCHARGES SLOW
ACCELERATION
CAPACITOR (C3 ON
CONTROL BOARD)
MOTOR STOPS
RESETS SLOW
ACCELERATION
CIRCUIT
UNIT READY
FOR NEXT WELD
NOTE 1: When interlock is open.
NOTE 2: When interlock is closed.
NOTE 3:
3 CR is not used on units with code no. 7926 and up.