Lincoln Electric SVM165-A Welder User Manual


 
A-2
A-2
INSTALLATION
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
Input Voltage/ 230Amps @ 300Amps @ 75°C Copper Wire Fuse
Frequency (Hz) 29 Volts 32 Volts AWG (IEC) or
(100% Duty Cycle) (60% Duty Cycle)
Sizes (MM
2
)
Breaker Size
208/60* 48 A 72 A 6 (16 mm
2
) 90 A
230/60 43 A 62 A 6 (16 mm
2
) 80 A
460/60 22 A 31 A 10 (6 mm
2
) 50 A
575/60 17 A 25 A 12 (2.5 mm
2
) 35 A
NOTE: Use #10 AWG Grounding Wire
*For 208V Input ONLY: The duty Cycle Rating at 300 Amps is 40%
TECHNICAL SPECIFICATIONS – POWER MIG 350MP
INPUT – SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
RECOMMENDED INPUT WIRE AND FUSE SIZES - SINGLE PHASE
Height
Width Depth Weight
31.79 in 18.88 in 38.78 in 255 Ibs
808 mm 480 mm 985 mm 116 kg
PHYSICAL DIMENSIONS
Wire Speed 50 – 700 IPM (1.27 – 17.8 m/minute)
WIRE SPEED RANGE
Standard Voltage/Frequency
Input Current @ 230Amp Rated Output Input Current @ 300 Amp Rated Output
208/230/460/575/60 Hz 48/43/22/17 Amps 72/62/31/25 Amps
Input
Voltage Duty Cycle
Amps Volts at Rated Amperes
208 40% 300 Amps 32 Volts
230/460/575 60% 300 Amps 32 Volts
208/230/460/575 100% 230Amps 29 Volts
Welding Current Range (Continuous)
Maximum Open Circuit Voltage Welding Voltage Range
5 – 350 Amps 67 Volts 10-45 Volts
POWER MIG 350MP