STATUS/FX/MODE-------------P00
battery 27.8 vdc
actual
DOWN STATUS PORT
STATUS/FX/METER-------------P00
absorb 28.8 vdc
setpoint
DOWN UP TOP PORT
STATUS/FX/MODE-------------P00
battery 27.8 vdc
temp compensated
DOWN UP TOP PORT
STATUS/FX/BATT---------------P00
absorb 00.0 hrs
time remaining
DOWN UP TOP PORT
STATUS/FX/BATT---------------P00
oat 24.0 hrs
time remaining
DOWN UP TOP PORT
STATUS/FX/BATT---------------P00
oat 13.6 vdc
setpoint
DOWN UP TOP PORT
BATT(ERY) Screens
battery actual• : battery voltage as measured by the Inverter
battery temp compensated• : not active in the OBX-IC2024S-120/60 Inverter (reads the same as the battery
actual reading)
absorb set point• : charger set point for absorb recharging cycle
absorb time remaining• : time remaining in absorb recharging cycle
oat set point• : battery set point for oat recharging cycle
reoat set point• : at this battery voltage, the charger restarts the oat recharging cycle
equalize set point• : charger set point for equalize recharging cycle
equalize time remaining: time remaining in equalize recharging cycle•
batt temp• : not active in the OBX-IC2024S-120/60 Inverter
The BATT MODE values cannot be changed in the STATUS screens.
STATUS/FX/BATT---------------P00
reoat 12.5 vdc
setpoint
DOWN UP TOP PORT
STATUS/FX/BATT---------------P00
equalize 00.0 hrs
time remaining
DOWN UP TOP PORT
STATUS/FX/BATT---------------P00
equalize 14.4 vdc
setpoint
DOWN UP TOP PORT
STATUS/FX/BATT---------------P00
batt temp. 255
(not in degree C/F)
DOWN UP TOP PORT
STATUS/FX/BATT---------------------
end of battery menu
UP TOP STATUS
STATUS/FX/PAGE 1----------------
choose category:
MODES METER BATT PG2
Status Batt(ery) Screens
Push <TOP> to return to the
rst METER screen.
Push <STATUS> to return
tothe“choosecategory”
STATUS screen.
Pressing the <BATT> soft key brings up the rst BATT screen.
Pressing the <DOWN> soft key brings up successive BATT screens.