Outback Power Systems OBX-IC2024S-120/60 Battery Charger User Manual


 
35
AC Input Operating Voltage Range
Note: This is the recommended AC input voltage range to be supplied to the Inverter. Voltages outside of this range will
not be accepted by the Inverter.
OBX-IC2024S-120/60 Inverter 80–150Vac(Vac=voltsAC)
AC Input Frequency Range
Note: If the AC input source is out of the range noted below, the Inverter will not connect or stay connected.
OBX-IC2024S-120/60 Inverter 54-66Hz
Maximum AC Input Current
An AC input source connected to the Inverter supplies power for two separate internal AC circuits – the AC
transfer switch and the battery charging system. The AC transfer switch transfers the AC input power to the
ACloads.TheInverter’sbatterychargerwill“backo”ifthetotalACloads—includingthecharger—exceed
theACinputcurrentlimit(defaultsettingis30Aac).This“InputLimit”canbeadjustedusingtheMATEto
avoid overloading a generator or trip a circuit breaker. If your generator cannot produce 30 Aac or you are
connecting to an AC input source that has a breaker that is rated for less than 30 Aac, please refer to page 20
to change this setting.
OBX-IC2024S-120/60 Inverter 30Aac(Aac=AmpsAC)
Maximum Current For Battery Charger (bulk stage)
OBX-IC2024S-120/60 Inverter ACMax=14Aac(Default=12Aac) DCMax=55Adc
Maximum AC Output Current
This is the amount of surge current that the Inverter will quickly supply for a split second. Depending on the
sizeofthesurge,theInvertercanbeoverloadedforaminimumtimeof5secondstoamaximumtimeof
30 minutes.
OBX-IC2024S-120/60 Inverter 70Aacfor1millisecond
Maximum Overcurrent Protection Ampacity
This rating species the proper overcurrent protection ampacity.
Bolt-in type class T DC fuses and should always be used in conjuncture with a disconnect mechanism. •
Inverters used in xed installations should use properly sized DC circuit breakers. •
A DC breaker includes both overcurrent protection and disconnect capability. •
OutBack Power Systems recommends Class T fuses for mobile installations where a DC disconnect is •
not required.
Model Ampacity DC Breaker DC Fuse
OBX-IC2024S-120/60 Inverter 175Adc OBB-175-125VCD-PNL Class T-300