2.3 Installing in a Rack
This section describes how to install the OfficeServ 7100 cabinet inside a 19-inch rack.
2.3.1 Cautions for Installation
Take the following cautions when installing the OfficeServ 7100 cabinet inside a rack:
y The 19” rack should be a standard electric equipment rack.
y When using an enclosed-type rack, check if the rack is properly ventilated. Vents
should be equipped on the side of the rack and fans should be attached to ventilate
cool air into the rack.
y For the enclosed-type rack that the fan is attached on the top, beware that the hot-air
generated in the system on the bottom part can go up and enters to the inlet port of the
installed system.
y When using an open rack, do not block the entrance of a port or fan of the OfficeServ
7100 system.
2.3.2 Tools Required
y A middle-sized Phillips screwdriver
y Two brackets and six screws for
attaching rack
y Two clamp screws
Figure 2.1 Tools for the Installation inside a Rack
2.3.3 Installing in a Rack
The procedure for installing the OfficeServ 7100 cabinet inside a 19-inch rack is as
follows:
1) Attach the cabinet bracket to the bottom surface of the OfficeServ 7100 cabinet and
fasten the bracket firmly with the two screws.
Figure 2.2 Rack Installation (1)