Tektronix 070-9197-00 Welding System User Manual


 
PS2520G and PS2521G Programmer Manual
19
Command Descriptions
This section provides an alphabetical listing and a detailed
description of each command. It also provides examples of each
command and what the query form might return.
*CLS (No Query Form)
Clears the following status data structures:
H Standard Event Status Register
H Operation Event Status Register
H Questionable Event Status Registers
H Error/Event Queue
*CLS
*CLS clears all event registers.
*ESE
Sets or returns the bits in the Event Status Enable Register
(ESER).The ESER enables the Standard Event Status Register
(SESR) to be summarized on bit 5 (ESB) of the Status Byte Register
(SBR). Refer to Figure 12 on page 52 for an illustration of the ESER.
*ESE <NRf>
*ESE?
<NR1> is a number from 0 to 255. The binary bits of the ESER are set
according to this value.
Syntax
Examples
Syntax
Parameters