Tektronix 070-9197-00 Welding System User Manual


 
Syntax and Commands
26
PS2520G and PS2521G Programmer Manual
On the PS2521G <NRf> ranges from 0 to 2.500 (amps) for Output 1
and Output 2 and 0 to 5.000 (amps) for Output 3.
<NR3>
SOURce:CURRent 1.5 sets the current limit to 1.5 amps.
SOURce:CURRent? returns 0.1000E+1 if the current limit setting is
1 amp.
[SOURce:]CURRent:PROTection:STATe
Sets the overcurrent protection on or off. The query form returns the
state of the overcurrent protection as either on or off.
[SOURce:]CURRent:PROTect:STATe <Boolean>
[SOURce:]CURRent:PROTect:STATe?
0|1|OFF|ON
OFF or 0 sets overcurrent protection off. ON or 1 sets overcurrent
protection on.
0|1
SOURce:CURRent:PROTect:STATe OFF sets the overcurrent
protection off.
SOURce:CURRent:PROTect:STATe? returns 1 if the overcurrent
protection is on.
ReturnsReturns
Examples
Syntax
Parameters
Returns
Examples