Tektronix 070-9197-00 Welding System User Manual


 
Syntax and Commands
22
PS2520G and PS2521G Programmer Manual
INSTrument:COUPle:TRACking
Selects independent, parallel-tracking, or series-tracking mode.
INSTrument:COUPle:TRACking <identifier>
INSTrument:COUPle:TRACking?
NONE|PARallel|SERies
NONE is independent mode
PARallel is parallel-tracking mode
SERies is series-tracking mode
NONE|PARallel|SERies
INSTrument:COUPle:TRACking NONE selects the independent mode.
INSTrument:COUPle:TRACking? returns SERies if series-tracking
mode is selected.
MEASure[:SCALar]:CURRent[:DC]? (Query Only)
Returns actual output current.
MEASure[:SCALar]:CURRent[:DC]?
<NR3>
MEASure:CURRent? might return 0.8E-2 to indicate that the load is
drawing 0.008 A (8 mA).
Syntax
Parameters
Returns
Examples
Syntax
Returns
Examples