Tektronix 070-9197-00 Welding System User Manual


 
Syntax and Commands
24
PS2520G and PS2521G Programmer Manual
OUTPut[:STATe]
Enables or disables the output of the power supply. ON (enabled) is
signified by a 1 and OFF (disabled) by a 0. The query form returns a
1 if the output is on and a 0 if the output is off.
OUTPut:STATe <Boolean>
OUTPut:STATe?
0|1|OFF|ON
0|1
OUTPut:STATe ON enables the power supply output.
OUTPut:STATe? returns 1 if the power supply output is enabled.
*RST (No Query Form)
Resets the control settings of the programmable power supply to a
set of known states but does not purge stored settings. Refer to
Table 5 for the reset state of the control settings.
Table 5: State of Control Settings after *RST
Front Panel
Control
Related Command State
OUTPUT
OUTPut[:STATe] OFF
CURRENT SET
[SOURce:]CURRent[:LEVel]
[:IMMediate][:AMPLitude]
0
VOLTS SET
[SOURce:]VOLTage[:LEVel]
[:IMMediate][:AMPLitude]
0
Syntax
Parameters
Returns
Examples