Tektronix 070-9197-00 Welding System User Manual


 
Syntax and Commands
28
PS2520G and PS2521G Programmer Manual
On the PS2520G, <NRf> ranges from 0 to 38.50 volts for Output 1
and Output 2 and 0 to 7.00 volts for Output 3.
On the PS2521G, <NRf> ranges from 0 to 22.50 volts for Output 1
and Output 2 and 0 to 7.00 volts for Output 3.
<NR3>
VOLTage:PROTection 24.5 sets the overvoltage protection to
24.5 volts.
VOLTage? returns 0.3100E+2 if the overvoltage protection setting is
31 volts.
*SRE
Sets the contents of the Service Request Enable Register (SRER).
The query form returns the contents of the SRER. Bit 6 of the SRER
is always zero. The bits on the SRER correspond to the bits on the
SBR. Refer to Table 9 on page 50 for an explanation of each bit in
the SBR. Refer to page 52 for additional information about enable
registers.
*SRE <NRf>
*SRE?
<NRf> is an integer from 0 to 255.
<NR1>
*SRE 8 sets bits of the SRER to 0000 1000.
*SRE? returns 2 if the SRER is set to 0000 0010.
Parameters
Returns
Examples
Syntax
Parameters
Returns
Examples