ZyXEL Communications 100IH Router User Manual


 
Prestige 100 and 100IH ISDN Router and Router/Hub
Troubleshooting 11-1
Chapter 11
Troubleshooting
This chapter covers the potential problems you may run into and the possible remedies. After
each problem description, some instructions are provided to help you to diagnose and to solve the
problem.
11.1 Problems Starting Up the Prestige
Table 11-1 Troubleshooting the Start-Up of your Prestige
Problem Corrective Action
None of the LEDs are on when
you power on the Prestige
Check the connection between the AC adapter and the Prestige.
If the error persists, you may have a hardware problem. In this case
you should contact technical support.
1.Check to see if the Prestige is connected to your computer’s serial
port.
VT100 terminal emulation
9600 bps
Cannot access the Prestige via
the console port.
2. Check to see if the
communications program is
configured correctly. The
communications software should
be configured as follows:
No parity, 8 Data bits, 1 Stop bit.