A SERVICE OF

logo

2 - 28
2 Wiring and Connection
MITSUBISHI CNC
(3) Connecting Mitsubishi serial signal output linear scale (when using MDS-D2/DH2-V2)
The FB signal of the linear scale is divided to each axis control inside the 2-axis drive unit. An external option unit is
not required.
(4) Connecting Mitsubishi serial signal output linear scale (when using two units of MDS-D2/DH2-V1)
The FB signal of the linear scale is divided to each drive unit with the signal division unit (MDS-B-SD).
CN2M
CN2L
CN3L
MDS-D2/DH2-V2
Cable prepared by user
Max. 30m
Linear scale
( Mitsubishi serial signal output )
Encoder type setting
Primary axis: SV025=A2xx
Secondary axis: SV025=D2xx
CNV2E cable
Max. 30m
Primary axis
Secondary axis
CNV2E cable
Max. 30m
MDS-D2/DH2-V1 MDS-D2/DH2-V1
MDS-B-SD
Encoder
division unit
CN2L
CN3L
CN2L
CN3L
Cable prepared by user
Linear scale
( SIN wave signal output )
Encoder type setting
SV025=A2xx
CNV2E cable
Max. 30m
Primary axis
Secondary axis
CNV2E-D
cable
Max. 30m
Encoder type setting
SV025=D2xx
Primary axis
Secondary axis