4 - 3
MDS-D2/DH2 Series Instruction Manual
4.1 Initial Setup
< Power supply unit >
MDS-D2/DH2-CV setting
When not using the external emergency stop: Set SW1 to "0"
When using the external emergency stop: Set SW1 to "4"
*Any other settings are prohibited.
4.1.2 Setting DIP Switch
Setting the DIP switches is necessary prior to turning ON the power. Setting of the DIP switches at the time of turning ON
the power is validated. The DIP switches shall be as the standard setting (all the switches OFF).

(
'
%
&
$
#


Power supply unit
(MDS-D2/DH2-CV)
The switches are OFF when facing bottom as illustrated.
M axis Setting unused axis
L axis Setting unused axis
S axis Setting unused axis
Unused axis can be set by turning the switches ON.
When there is unused axis for the drive unit,
set unused axis.