Craftsman 113.248510 Saw User Manual


 
trouble shooting -- electronics
MODEL 113.248440 & 113.248510
PROBLEM
I
No display when
is pressed.
Display shows
I
1
PROBABLE CAUSE
1. Battery incorrectly
installed or missing.
2. Battery contacts dirty
or corroded.
3. Battery dead.
4. Digital display failure.
1. Normal display when
battery is first installed in
unit.
2. Bevel display was not
ref-set.
3. Poor battery contact to
indicator display leads
causing intermittent
power to display.
4. Digital display failure.
SUGGESTED CORRECTIVE ACTION
.......... _ ...... -- ..... __ ...... --H
- Adjust battery position in compartment.
- Install battery.
- Clean battery contacts.
- Replace battery Battery is 6 volt, size J, !
alkaline type. ,
- Have electronics checked by qualified
technician. Repair service available at nearest
Sears Store. --
- No action required.
- Follow procedure for setting bevel reference
point in this manual.
- Clean battery contacts. Adjust battery position
in compartment.
- Have electronics checked by qualified service
technician. Repair service available at nearest
Sears store.
Display dim. 1. Low battery voltage. - Replace battery. Battery is 6 volt, size J.
alkaline type.
2. Temperature below 32° F. - Allow saw to warm above 32° F.
Display dark. 1. Temperature above 120°F. - Allow saw to cool below 120° F.
Display blanks after 1. Normal. - Press IO"_OF_]key. Display should return.
a few minutes.
Display shows 1. - Reset bevel zero reference.
FFc,:EEl
Display will reset to
zero but immediately
shows when bevel is
moved,
I EEEEI
Head tilted too rapidly
for digital display to
monitor.
1. Encoder or digital
display defective.
1. Wrong display function
selected.
2. Encoder or digital
display defective.
3. Rib on lower slide
not engaging encoder.
i _ Have electronics checked by qualified
i technician, Repair service available at nearest
Sears store.
- Select bevel function.
- Have electronics checked by qualified
technician. Repair service available at nearest
Sears store.
- Have electronics checked by qualified
technician. Repair service available at nearest
Sears store.
Display does not
change when bevel
is moved.
41