Craftsman 113.29921 Saw User Manual


 
Motor Specifications and Electrical Requirements 1
_ower Supply and Motor Specifications
WARNING: To avoid electrical hazards, fire haz-
ards or damage to the tool, use proper circuit pro-
tection. Your tool is wired at the factory for
operation using the voltage shown. Connect toot
to a power line with the appropriate voltage and a
15-amp branch circuit. Use a 15-amp time delay
type fuse or circuit breaker. To avoid shock or fire,
if power cord is worn or cut, or damaged in any
way, have it replaced immediately.
The A-C motor used in this tool is a relay start, non-revers-
ible type, having the following specifications:
Rated HP 1
Voltage 110-120
Amperes 1t 5
Hertz (Cycles) 60
Phase Single
RPM 3450
Rotation of Shaft Counterclockwise
i ,,u ..............
General Electrical Connections
DANGER: To avoid electrocution:
1. Use only identical replacement parts when ser-
vicing, Servicing should be performed by a
qualified service technician.
2, Do not use in rain or where floor is wet.
This tool is intended for indoor residential use
.........only.
7
WARNING: Do not permit fingers to touch the ter- |
minals of plug when installing or removing the
plug to or from the outlet.
110-120 Volt, 60 Hz. Tool Information
NOTE: The plug supplied on your toof may not fit into the
outtet you are planning to use Your local electrical code
may require slightly different power cord plug connec-
tions if these differences exist refer to and make the
proper adjustments per your local code before your tool
isplugged in and turned on
In the event of a malfunction or breakdown, grounding
provides a path of least resistance for electric current to
reduce the risk of electric shock This toot is equipped
with an electric cord having an equipment-grounding con-
ductor and a grounding plug, as shown,, The plug must
be plugged into a matching outlet that is properly
installed and grounded in accordance with all local codes
and ordinances
Do not modify the plug provided, If it will not fit the outlet,
have the proper outlet installed by a qualified electrician
A temporary adapter may be used to connect this plug to
a 2-prong outlet as shown if a properly grounded three
prong outlet is not available,. This temporary adapter
should be used only until a properly grounded three
prong outlet can be installed by a qualified electrician
The green colored rigid ear', lug or the like, extending
from the adapter must be connected to a permanent
ground such as a properly grounded outfet box
Improper connection of the equipment-grounding con-
ductor can result in a risk of electric shock The conduc-
tor with insulation having an outer surface that is green
with or without yellow stripes is the equipment-grounding
conductor If repair or replacement of the electric cord or
plug is necessary, do not connect the equipment-ground-
ing conductor to a live terminal
If the grounding instructions are not completely under-
stood, or if you are in doubt as to whether the tool is prop-
erly grounded check with a qualified electrician or service
)ersonnel.
WARNING: If not properly grounded, this tool can
cause an electrical shock, particularly when used
in damp locations, in proximity to plumbing, or out
of doors_ If an electrical shock occurs there is the
potential of a secondary hazard, such as your
hands contacting the sawblade.
Properly
Grounded
3-Prong Outlet
\ J
In 111
3-Prong Plug
G!ounding
Prong
Grounding Lug _
Make sure this
Is Connected
to a Known
Ground
2-Prong
Outlet
NOTE: The adapter illustrated is for use only if you
already have a properly grounded 2-prong outlet
7