Graco 24P822 Welding System User Manual


 
Setup Screens
Setup Screens
8 and 9
Use these screens to set up the pressure transducers.
The screens are identical, except Screen 8 is for
transducer 1 and Screen 9 is for transducer 2.
Selecting a transducer and a pump activates closed
loop pressure control.
Figure 31 Setup Screens 8 and 9 (Screen 8 shown)
Setup Screens 8 and 9 Key
Select from the dropdown options to
enable the transducer.
For systems with multiple pumps and
one display, select the desired pump (1
to 8), using the pull-down menu. Enables
closed loop pressure control and assigns
the transducer to a pump.
Enter the calibration scale factor from the
transducer label.
Enter
the calibration offset value from the
trans
ducer label.
Displays the current transducer reading.
Exit data editing.
Move between Setup Screens, fields on
a screen, or to increment/decrement the
digits when editing number fields.
Figure 32 Select Pressure Transducer
Figure 33 Select Pump, to Enable Closed Loop
Pressure Control
Figure 3
4 Enter Calibration Scale Factor
Figure 35 Enter Calibration Offset Value
2
4
3A2527D