Lincoln Electric SVM162-B Welding System User Manual


 
F-15F-15
PRECISION TIG 275
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TROUBLESHOOTING & REPAIR
TROUBLESHOOTING GUIDE Observe Safety Guidelines
detailed in the beginning of this manual.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
FUNCTION PROBLEMS
The meter does not display V (volt)
or minimum current.
NOTE: BEFORE REPLACING A
CONTROL BOARD
If an Advanced Control Panel is
installed, remove it and replace
the Jumper in connector J-3. If
the machine functions normally,
the Advanced Process panel or
harness is defective.
1. Check that either the advanced
control board or jumper plug is in
J3 on the control board.
1. Check R1 potentiometer and
associated leads between the
control board and plug J9. See
the Wiring Diagram.
2. The control board may be faulty.
CAUTION