Lincoln Electric SVM166-A Welder User Manual


 
LN-15
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
RESOLUTION
DESCRIPTION/
DEFINITION
0081
0082
0086
Average motor over cur-
rent shutdown
Locked rotor condition
on the wire drive motor.
Trigger lockout.
TROUBLESHOOTING & REPAIR
F-9 F-9
FAULT CODES
NOTE: If more than one fault message is being displayed, perform all the checks for the faults
before replacing the printed circuit board
The wire drive motor has overheated.
Check to make sure the electrode
slides easily through the liner of the
gun.
Reduce the spindle brake resistance.
Reduce the amount of tension in the
wire drive tension arm.
For the best results, use only Lincoln
electrodes.
•Wait 10 minutes for the wire feeder to
cool.
•Verify that nothing is jammed in the
wire drive or gears.
The ripple of the power source OCV
is too high, greater than 110V.
(Across the Arc Models only)
Verify that the power source is
reconnected for the proper input
voltage.
Repair or replace the power source.
The power source does not conform
to NEMA.