4 Connection
MITSUBISHI CNC
94
4.3.3.1 Handle Numbers
Unit configuration decides handle Nos.
"ENC": Connector on control unit "MPG": Connector on operation panel I/O unit
(Note) If one handle is only connected to "MPG", the handle connected to "ENC" 1ch will still be treated as the 3rd
handle. "ENC" 2ch is not employed when an operation panel I/O unit is used.
4.3.4 Connecting with Machine Operation Panel
Connect the machine operation panel to the connector CG31, CG32, CG33, CG34, CG35 or CG36.
<Related items>
Cable drawing: "Cable: F351 Cable"
Connector pin assignment: "General Specifications: Operation Panel I/O Unit" (CG31/CG32/CG33/CG34/CG35/
CG36 connector)
Operation panel I/O unit (FCU7-DX71x/ DX72x/ DX73x/DX621) 1st handle 2nd handle 3rd handle
Used "MPG" 1ch "MPG" 2ch "ENC" 1ch (Note)
Not used "ENC" 1ch "ENC" 2ch -
CG31/CG33/CG35
CG32/CG34/CG36
F351
Operation panel I/O unit
Machine Operation Panel (Example)