Mitsubishi Electronics M700V Router User Manual


 
4 Connection
MITSUBISHI CNC
106
4.4.4 Connecting FCUA-DX141 Unit with Analog Input/Output Signal
For the analog input/output signal, connect the FCUA-R031 cable to "AIO". Up to four input points and one output point
can be connected for the analog input/output signal. When manufacturing the FCUA-R031 cable, use the FCUA-CS000
connector set (optional, with both ends).
Input/output circuit
CAUTION
1. Connect the cable to the designated connector. Incorrect connections could damage the device.
2. Do not connect or disconnect the connection cables between each unit while the power is ON.
AIO
1
10
11
20
FCUA-R031
FCUA-DX141
Pin No.
Analog I/F
DAC
220
R
R
150
ADC
AI0
A0
FCUA-DX141
7
GND
GND
G
ND
GND
AI1
AI2
AI3
13
12
2
3
150
150
150
1
11
5
15
0V (RG)
0V (RG)
Connector pin No.
Input
Output