E70 Series Connection Manual
Appendix 1.14 F034/F035 Cable
131
Appendix 1.14 F034/F035 Cable
Max. cable length: 15m (the maximum length of the cable when connected to the control unit via other
units)
Application: RS232C I/F cable (for control unit)
(Note 1) Fold the cable shield over the sheath, and wrap copper foil tape over it. Connect the wound copper foil
tape to GND plate of the connector.
(Note 2) Signal names in parentheses "( )" are generally used.
(Note 3) Connect to the serial communication connector of the control unit. Use G031/G032 cable when
connecting to the serial communication connector of the display unit.
[SIO]
Connector: 10120-3000VE
Case: 10320-52F0-008
Recommended manufacturer: 3M
Wire material: UL1061-2464
AWG24×12P
Recommended manufacturer: Oki
Electric Cable
[1ch][2ch]
Connector: CDB-25S
Contact: CD-SC-111×9
Lock nut: HD-LNA×2
Recommended manufacturer:
Hirose Electric
Cable name 1ch 2ch
F034 cable
○
F035 cable
○○
○ : Usable channel
1ch
SIO
2ch
SIO 1ch
FG
12
2
13
3
14
4
16
6
1
17
7
18
8
19
9
20
10
11
SD1(TXD1)
RD1(RXD1)
RS1(RTS1)
CS1(CTS1)
ER1(DTR1)
DR1(DSR1)
Reserved
Reserved
0V
SD2(TXD2)
RD2(RXD2)
RS2(RTS2)
CS2(CTS2)
ER2(DTR2)
DR2(DSR2)
Reserved
Reserved
0V
2
3
4
5
20
6
8
9
7
2
3
4
5
20
6
8
9
7
2ch