E70 Series Connection Manual
2.7 External Power Supply Unit
43
2.7 External Power Supply Unit
(Note 1) PD25 will not be turned ON by the ON/OFF switch immediately after the power OFF. Wait at least 2
seconds, and then turn the power ON.
(Note 2) The power supply configuration for NC devices depends on the machine. Appropriate circuit protector
must be selected by machine builder according to the load of the machine.
(Note 3) PD25 does not comply with 100VAC.
Dimension and names of parts
[PD25]
<Mounting direction and clearance>
Mount the external power supply unit vertically and so that it is visible from the front. Provide space for heat
dissipation and ventilation.
Item PD25
Input power voltage
200 to 230VAC
+10%-15%
50/60Hz±1Hz
Output current 3A
Dimension 130mm × 65mm × 230mm
Mass 1.5kg
Output holding time 300ms
220
230
2-R3
230
208
AC IN
ON/OFF SW
ON/OFF
POWER
DC OUT
65
30
6
6
130
FAN ALARM
(1)
(2)
(3)
(5)
(4)
20mm 20mm
100mm
100mm