Mitsubishi Electronics M700V Router User Manual


 
Appendix 1 Cable
MITSUBISHI CNC
146
Appendix 1.28 G023/G024 Cable
Max. cable length: 20m (the maximum length of the cable when connected to the control unit via other
units)
Application: Manual Pulse Generator cable (5V)
(for connection to control unit)
(Note) Fold the cable shield over the sheath, and wrap copper foil tape over it. Connect the wound copper foil
tape to GND plate of the connector.
[ENC]
Connector: 10120-3000VE
Case: 10320-52F0-008
Recommended manufacturer: 3M
Wire material:
UL1061-2464 AWG22×6P
Recommended manufacturer:
Oki Electric Cable
[1ch][2ch]
Crimp terminal: V1.25-3 ×8
Recommended manufacturer: JST
Cable name 1ch 2ch
G023 cable
G024 cable
○○
: Usable channel
ENC
8
18
10
5
7
17
20
15
5V
GND
5V
GND
1ch
2ch
FG
ENC
HA1A
HA1B
HA2A
HA2B