4 Connection
MITSUBISHI CNC
102
When connecting to the operation panel I/O unit
Station No. 1, 2, 7, 8 (or 1, 2, 3, 7, 8) are occupied by the operation panel I/O unit. (Station No. 7 and 8 are reserved
for manual pulse generator.)
The maximum numbers of stations and I/O points assigned to remote I/O unit(s) via RIO3 are as follows.
Setting example 1
Number of occupied stations: 1
Total number of occupied stations: 1
Setting example 2
Number of occupied stations: 2 2
Total number of occupied stations: 4 (Maximum configuration)
Operation panel I/O unit type
Max. number of stations (RIO3
connection)
Max. number of I/O points
(RIO3 connection)
Remote I/O
Rotary switch
Setting range
FCU7-DX711 4 stations (No. 3 to 6) 128 points/128 points 2 to 5
FCU7-DX621/721/731 3 stations (No. 4 to 6) 96 points/96 points 3 to 5
㸩
2
FCU7-DX711 FCUA-DX101
㸩
4
5
㸩
2
3
FCU7-DX711 FCUA-DX111
or
FCUA-DX121
FCUA-DX111
or
FCUA-DX121