e-STUDIO160/200/250 TROUBLESHOOTING 4 - 26 December 2002 TOSHIBA TEC
4.1.7 Paper jam in finisher
EA1 Finisher paper transport delay jam
Is there paper remaining on the transport path in the finisher or main unit?
Remove the paper.
Is the connector J10 on the finisher controller PWA disconnected?
Is the harness connecting the finisher controller PWA and inlet paper sensor broken?
Connect the connector securely. Replace the harness.
Is the inlet paper sensor working properly? (Check the movement of the actuator.)
1. Connect the connector of the inlet paper sensor securely.
2. Attach the actuator securely if its shaft is out of place.
3. Replace the inlet paper sensor.
Replace the finisher controller PWA.
EA2 Finisher paper transport stop jam
Is there paper remaining on the transport path in the finisher or main unit?
Remove the paper.
Is the connector J10 on the finisher controller PWA disconnected?
Is the harness connecting the finisher controller PWA and inlet paper sensor broken?
Connect the connector securely. Replace the harness.
Is the inlet paper sensor working properly? (Check the movement of the actuator.)
1. Connect the connector of the inlet paper sensor securely.
2. Attach the actuator securely if its shaft is out of place.
3. Replace the inlet paper sensor.
Replace the finisher controller PWA.
YES
NO
YES
NO
NO
YES
YES
NO
YES
NO
NO
YES