e-STUDIO160/200/250 TROUBLESHOOTING 4 - 62 December 2002 TOSHIBA TEC
Step
1
2
3
4
5
Cause/Defect area
Process unit installation
Process unit
(main charger)
HVPS (main charger)
Measures
Re-install process unit securely.
Clean terminals.
Replace the process unit or charger wire.
Adjust output from HVPS, or replace defec-
tive HVPS.
Replace the process unit, laser scanner unit,
HVPS, or main PWA.
Check items
Process unit securely installed?
Charger wire terminals/grid termi-
nals (process unit) and corre-
sponding terminals (main body)
stained?
Is there any disconnection in the
charger wire?
High-voltage output defective?
If problem persists after measures
are applied, or there is no prob-
lem found in above check, follow
procedure described in right col-
umn.
Feeding direction
(4) Solid copy