e-STUDIO160/200/250 TROUBLESHOOTING 4 - 28 December 2002 TOSHIBA TEC
EA5 Finisher stapling jam
Is there paper remaining on the transport path in the finisher or main unit or on the stapling tray?
Remove the paper.
Is the jam cleared by taking off the staple cartridge from the finisher and removing the staple
sheet which was slid out of the staple case?
End
Is the connector J8 on the finisher controller PWA disconnected?
Is the harness connecting the finisher controller PWA and stapling home position sensor bro-
ken?
Connect the connector securely. Replace the harness.
Is the stapling home position sensor working properly?
1. Connect the connector of the stapling home position sensor securely.
2. Replace the stapling home position sensor.
Replace the finisher controller PWA.
EA6 Finisher early arrival jam
Is there paper remaining on the transport path in the finisher or main unit?
Remove the paper.
Is the connector J10 on the finisher controller PWA disconnected?
Is the harness connecting the finisher controller PWA and inlet paper sensor broken?
Connect the connector securely. Replace the harness.
Is the inlet paper sensor working properly? (Check the movement of the actuator.)
1. Connect the connector of the inlet paper sensor securely.
2. Attach the actuator securely if its shaft is out of place.
3. Replace the paper inlet sensor.
Replace the finisher controller PWA.
NO
YES
NO
NO
YES
NO
YES
YES
NO
YES
NO
NO
YES
YES