e-STUDIO160/200/250 ADJUSTMENT ITEMS 1 - 60 December 2002 TOSHIBA TEC
Paper cassette Cassette selection value Code
Cassette 1 1 440
Cassette 2 2 441
Cassette 3/4 3/4 444
Bypass 0 442
LCF 3 443
(3) In order to set the distance "D" to 50 mm.
Notes: 1. An increase in the value increases the distance "D" (0.4 mm/step).
2. Adjustment value is able to be input within the range of 0 - 15. Default adjustment value is 8.
In case of the cassette 1 feeding (Code "440"), adjustment value is within the range of 0 - 40
(Default adjustment value is 23).
3. Since the cassette 1 adjustment value becomes a standard for all adjustments, this adjustment
must always be performed in the order stated above.
4. The adjustment is made for each paper cassette. Paper cassette selection values (1) and cor-
responding codes (3) in paper cassette adjustment.
5. To confirm the adjustment of ADU (code 445), do not print a test print in the procedure in (1),
but copy the TEST CHART.