Toshiba e-Studio160 Work Light User Manual


 
December 2002 TOSHIBA TEC 4 - 79 e-STUDIO160/200/250 TROUBLESHOOTING
(21) Skew (inclined image)
Step
1
2
3
4
5
6
7
8
9
10
Cause/Defect area
Cassette/LCF
Paper feed roller
Registration roller
Pinch roller
Paper guide
Original scale
Carriage 1
Measures
Re-install cassette or LCF properly.
Reduce paper to 550 sheets or less. (1250
sheets each or less for LCF.)
Reinsert paper with reverse side up or change
paper.
Adjust side guide.
Clean roller surface with alcohol, or replace
roller.
Clean roller surface with alcohol, or replace
roller.
Re-mount or replace spring.
Re-install paper guide securely.
Adjust original scale.
Adjust carriage 1
Check items
Cassette or LCF properly in-
stalled?
Too much paper loaded in cas-
sette or LCF?
Paper in cassette or LCF curled?
Cassette or LCF side guides prop-
erly installed?
Paper feed roller dirty?
Registration roller dirty?
Pinch roller spring out of place?
Paper guide improperly
mounted?
Original scale slanted?
Carriage 1 slanted?
Feeding direction
Moire