December 2002 TOSHIBA TEC 1 - 3 e-STUDIO160/200/250 ADJUSTMENT ITEMS
- Internal tray full (when finisher bridge installed)
(e-STUDIO200/250 series)
- No paper in the cassette 1
- No paper in the cassette 2
- No paper in the cassette 3
- No paper in the cassette 4 (e-STUDIO200/250 series)
- No paper in the LCF (e-STUDIO200/250 series)
- Cassette 1 is not ready
- Cassette 2 is not ready
- Cassette 3 is not ready
- Cassette 4 is not ready (e-STUDIO200/250 series)
- LCF is not installed (e-STUDIO200/250 series)
Front cover or side cover of the copier is open
Cover of the job separator is open
Cover of the off set catch tray is open
Cover of the bridge cover is open
(e-STUDIO200/250 series)
Cover of the ADU is open
Side cover of the cassette 2 is open
Side cover of the cassette 3 is open
Side cover of the LCF is open
(e-STUDIO200/250 series)
Finisher joint is open (e-STUDIO200/250 series)
No staples (displayed only when stapling is designated)
(e-STUDIO200/250 series)
C01 Main motor drive error
C02 to C03 Reserved
C04 PFP main motor drive error
C05 Reserved
C06 LCF feed motor error (e-STUDIO200/250 series)
C07 to C10 Reserved
C11 to C12 Reserved
C13 Cassette 1 error
C14 Cassette 2 error
C15 Cassette 3 error
C16 Cassette 4 error (e-STUDIO200/250 series)
C17 Reserved
C18 LCF tray error (e-STUDIO200/250 series)
C19 LCF feed motor abnormal (e-STUDIO200/250 series)
C20 Reserved
Classification Error code Machine status
Other operator calls
CALL SERVICE from drive
system
Temporary paper supply
mechanism error