e-STUDIO160/200/250 ADJUSTMENT ITEMS 1 - 90 December 2002 TOSHIBA TEC
8. Settings for the date and time
For details, see chapter 5 of the Operator's Manual.
PROGRAM
0
3 10
INITIAL SETUP
DATE & TIME
SETTING
DD-MM-YYYY DAY HH:MM
15-01-2003 WED 10:10PM
1.10 MAIN PWA replacement procedure
1. Downloading of the MAIN PWA firmware
For details, see chapter 5 of the Service Handbook.
2. Execution of 08-388 mode. (Reading of the total counter value)
3. RAM Clear with the [1], [3], and [*] keys.
4. Execution of 08-665 mode (05: adjustment clear/08: programming clear)
5. RAM Clear with the [1], [3], and [#] keys.
Power ON
0 8
SET
Power OFF
or
START
3
88
Power ON
1 *
Power OFF
3
Warming up
Power ON
1 #
Power OFF
3
Warming up
Power ON
0 2
SET
or
START
1
44
Power ON
0 8
SET
Power OFF
or
START
6
56
6. Download the scanner PWA firmware, if necessary, after confirming the version of it.
7. Settings for the country code or region code
9. Writing in memory (entering the drum counter value (DRUM COUNTER), long size counter value
(A3/LD) and short size counter value (A4/LT)).
For the setting value, refer to the DRUM UNIT LIST printed before replacing the MAIN PWA.
When the DRUM UNIT LIST is not printed, perform the following setting.
Drum counter value: Find a remainder by dividing the total counter value (08-351) by the pro-
cess unit life value (27k or 33k).
Enter the value obtained by multiplying the remainder by 10.
Long size counter value: Enter "0."
Short size counter value: Enter the remainder obtained by dividing the total counter value (08-351)
by the process unit life value (27k or 33k).
For the setting procedures, refer to section 1.2.5 of the Service Handbook.
Setting the country or region code for the
CND .
CND:
With Fax kit
See the 1.2.6 of the Service Handbook (GD-1061).
Without Fax kit
LT:
A4:
8 6