December 2002 TOSHIBA TEC 1 - 13 e-STUDIO160/200/250 ADJUSTMENT ITEMS
1.2.2 System mode
<Key used in operation> <Display messages>
0 8
Digital Keys
Digital Keys
Enter code
Setting value
TEST MODE D
MC=
( C/S used to correct value)
Power ON
Cancel
TEST MODE D
MC=204
DT= 1
Setting value
TEST MODE D
MC=
204
Enter code
SET
or
START
SET
or
START
Setting item
Selection of external counter
0: No external counter
1: With coil controller
2: Non-standard: With copylizer/key
card
3: With key counter
Auto clear [sec]
0: Invalid 1: 15s 2: 30s 3: 45s 4: 60s
5: 75s 6: 90s 7: 105s 8: 120s
9: 135s 10: 150s 11: 180s 12: 210s
13: 240s 14: 270s 15: 300s
Auto low power 0: Invalid 1: Valid
(Time is set on panel.)
Auto sleep 0: Invalid 1: Valid
(Time is set on panel.)
Display for key counter setting
0: Set key copy counter
1: ASK CASHIER TO SWITCH ON
* Valid when 08-202 is set to 3 (With key
counter).
SYSTEM MODE (08) ITEMS
Code
202
204
205
206
207
Factor
SYS
SYS
SYS
SYS
SYS
Mode
ALL
ALL
ALL
ALL
ALL
Image
quality
mode
Default
0
3
1
1
0
Acceptable
value *1
0-3
0-15
0-1
0-1
0-1
Refer to
page