Toshiba e-Studio250 Work Light User Manual


 
e-STUDIO160/200/250 ADJUSTMENT ITEMS 1 - 66 December 2002 TOSHIBA TEC
1.5 Sharpness (HPF) Adjustment
If the user wants to change the image sharpness to softer or harder, adjust the HPF intensity in adjust
mode "05".
Image mode Adjustment item
Photo/Text Photo Text
620 621 622 HPF intensity
Code
Power ON
0 5
Digital Keys SET Digital Keys SET INT START INT Power OFF
(Enter code) (Set the value) (Test copy)
<Keys used in operation>
or
START
or
START
Notes: 1. Adjustment value is able to be input within the range of 0-99.
2. Default value.
Code Default value
620 1
621 2
622 3
Remarks
No. of units: HPF table number
0: Use of default value
1: Text/Photo mode
2: Photo mode
3: Text mode
4-9: Unused
No. of tens: Filter combination intensity
0: Use of default value
1-9: Filter combination intensity
(The larger the intensity co-
efficient the stronger the in-
tensity.)