Toshiba e-Studio250 Work Light User Manual


 
December 2002 TOSHIBA TEC 1 - 53 e-STUDIO160/200/250 ADJUSTMENT ITEMS
1.3 Image Quality Control
If the user wants to change the image density, adjust the image density in adjust mode "05."
Follow the procedure below to adjust the image density to suit the user’s preferences while comparing the
image obtained in the test copy and the currently entered allowable values.
<Keys used in operation>
Notes: 1. Adjustment value is able to be input within the range of 0 - 255.
2. Default values are as following.
Code Default value
501 139
503 133
504 130
505 28
506 18
507 20
508 13
509 20
510 18
512 140
514 133
515 130
Original mode Adjustment item Remarks
Photo/Text Photo Text
503 501 504 Standard PPC Manual density The larger the value, the darker
center value the image
505 506 507 Light side Manual density The larger the value, the lighter
the light range
508 509 510 Dark side Manual density The larger the value, the darker
the dark range
514 512 515 Standard PPC Automatic density The larger the value, the darker
the image
Code
Power ON
0 5
Digital Keys SET Digital Keys SET INT START INT Power OFF
(Code) (Set the value) (Test print)
or
START
or
START