Videk 2030 Stud Sensor User Manual


 
K11020 VisionSensor™ 2030 User Manual, Rev. E, Software ver. 3.1.1000, August 3, 2007 - 42
Save Settings
To nd out the Reader ID and rmware version, plug your VisionSensor 2030 into your USB or RS232
cable, open a text editor program (i.e. Notepad, Microsoft Word...) and read the following code:
Reader ID and Firmware
You will get a text string with your rmware version and VisionSensor™ 2030 ID number (serial number):
Example: Xap/i33083266none0010010969A07D0016VS-3.1.1000
Template: Xap/iaaaabbbbccccddddddddddeffggggghh-h.h.hhhh
Xap/i - internal product ID (5 char)
aaaa - base rmware version number (4 char), 3308 in above example
bbbb - bootloader rmware version number (4 char), 3266 in above example
cccc - radio rmware version number (4 char), none in above example
dddddddddd - reader serial number (10 char), 0010010969 in above example
e is “A” if running rmware is the application, “B” if bootloader (1 char), A in above example
ff - supplemental internal ID (2 char), 07 in above example
ggggg - display ag and ash le system version (5 char), D0016 in above example
hh-h.h.hhhh - application rmware ver number (11 char), VS-3.1.1000 in above example
Additional control characters will also appear in the output string.
Note: Videk will periodically release new rmware for VisionSensor™ 2030 units. For information on latest
rmware versions, call Videk at (585) 292-6210 or (800) 248-4335. To upgrade the rmware please visit
Videk Website at http://www.videk.com/support/downloads.htm and follow instructions.
4.7 - Reader ID and Firmware Version
4.8 - Reader Settings Lock
To lock or unlock the current settings on your reader please scan the codes below:
Reader Settings Locked Reader Settings Unlocked
NOTE: Prex and Sufx programming codes, memory transfer and delete commands, “Clear All