30 Chapter4
Screens
HSCSD screen
4. Master timeslot
The Master timeslot field indicates which timeslot is used for the
master TCH. As the slave TCH is always in the timeslot immediately
after the master, changing this field sets the slave timeslot to the value
“master timeslot plus one”.
On a master unit or a single unit, the value of this field is always the
same as the TCH timeslot field on the Cell Status screen.
NOTE The default is reset when the instrument type (see page 24) is selected.
5. Slave timeslot
The relative position of the slave timeslot is fixed at +1. Therefore, if the
master timeslot is set to 3, the slave timeslot is set to 4. Likewise, as the
master timeslot changes, this field also changes.
On a slave unit, the value of this field is always the same as the TCH
timeslot field on the Cell Status screen.
NOTE The default is reset when the instrument type (see page 24) is selected.
Type integer
Units none (timeslot)
Limits 2 thru 5
Default 4
Type read-only
Values 3 thru 6
Default 5