Atlas Air Compressor Air Compressor User Manual


 
Instruction book
2920 1521 00 31
Period Running
hours
Service
Plan
See
section
See
notes
below
table
Operation
Daily
-- -- 3.4 -- Drain condensate
"
-- -- -- -- On SF Full-Feature, check dewpoint
Monthly
250 -- 5.1 1 Inspect air filter
3-monthly
500 -- -- -- Check pressure drop over Atlas Copco filters
(optional)
6-monthly
-- -- 5.4 -- Operate safety valve
"
-- -- -- -- Clean compressor
"
-- -- -- -- On SF Full-Feature, brush or blow off the finned
surface of the condenser
"
-- -- -- -- On SF Full-Feature, clean condensate trap
internally
Yearly
-- -- 5.4 -- Test safety valve
"
-- -- -- -- Have electrical components/shut-down switch
tested
"
2500
I
5.2 -- Check tension/condition of V-belt(s)
"
5000
A
5.1 -- Replace air filter
"
5000
A
-- 2 Have ball valve mechanism of condensate trap
inspected
"
5000
A
5.2 -- Replace V-belt(s)
2-yearly
5000
B
-- 2 Have orbiting scroll bearing greased
"
10000
B
-- 2 Clean compressor element fan and duct. Clean
compressor element fins, have seals replaced
"
10000
B
-- 2 Have pin crank bearings greased
Notes:
1. Check more frequently if operating in a dusty atmosphere. Check for cleanness and damage.
Replace a dirty or damaged filter by a new one.
2. Consult Atlas Copco.