Atlas Air Compressor Air Compressor User Manual


 
Instruction book
2920 1521 00 45
8.3 Status data menu
The status data submenu gives information regarding the status of the compressor protection
functions (shut-down, service warning and warning) and allows resetting of a shut-down and service
condition.
Procedure
Starting from the Main screen (see section 8.1.2):
- Press the key "Menu" (F1), the option "Status data" will be followed by a horizontal arrow
- Press the tabulator key (5)
8.3.1 No message exists
In this case, LED (7) is out and the message on the display indicates that all conditions are normal
(Fig. 8.5):
All Conditions are OK
Menu Help
F1 F2 F3
Fig. 8.5 Example of a status data screen
8.3.2 A shut-down message exists
In case the compressor is shut down, LED (7) will blink. A shut-down message exists after an
emergency stop or after the temperature switch (TSHH20-Fig.2.8) has tripped (indicated on the
display as Aux. Equipment Overload).
In case of a shut-down due to an emergency stop, a screen similar to the one below will appear:
Emergency Stop Open
Shutdown Open
Menu *** *** Reset
F1 F2 F3
Fig. 8.6 Example of a status data screen
1. The indicators (***) are blinking. The screen shows that the compressor is shut down due to an
emergency stop. The contacts of the emergency switch are open. The setting of the shut-down is
open.