Instruction book
2920 1521 00 58
Suppose the command to stop the compressor at 18:00 must be added to the list of Monday:
- 06:15 start
- 06:15 pressure band 1
3. Press the tabulator key (5), following screen appears:
Monday
→
Tuesday
Wednesday
↓
Menu Delete
F1 F2 F3
4. Scroll through the display until "Monday" is followed by a horizontal arrow. Press the tabulator key
(5). Scroll through the compressor start/stop/pressure band commands until the first empty
command line is indicated by symbol ┤ on the screen.
5. Press the key "Modify", the first two digits of the command start blinking. Enter "18:00 stop" using
the scroll keys ↓ or ↑ to modify a field and the tabulator key (5) to jump from one field to another.
6. Press the key "Program" to program the new command or the key "Cancel" to quit without
reprogramming.
Adding a command between two existing commands
1. Suppose the command 17:00 pressure band 2 must be added to following list:
- 06:00 start
- 06:00 pressure band 1
- 18:00 stop
2. The regulator does not allow to enter a new command which is situated timewise before the last
command in the list.
3. Scroll through the display until the command before which the new command must be entered is
followed by symbol ┤ (in the example above: 18:00 stop) and press the key "Modify". Change this
command to the new command (in the example above: 17:00 pressure band 2) and press the
"Program". Press the ↓ key, add the last command of the list (in the example above: 18:00 stop)
and press the key "Program".
8.11.5 To delete commands
1. Starting from the Main screen (see section 8.1.2):
- press the key "Menu" (F1)
- press the ↓ key until the option "Modify parameters" is followed by a horizontal arrow
- press the tabulator key (5) to activate the menu