Atlas Air Compressor Air Compressor User Manual


 
Instruction book
2920 1521 00 52
8.9.2 Modifying protections for Dryer LAT on Full-Feature machines
1. Consult the section above to select the parameter Dryer LAT (Low Ambient Temperature):
Dryer LAT 10 °C
Warning Maximum 25 °C
Back Modify
F1 F2 F3
Fig. 8.14 Modify parameters menu
2. The screen shows that the Dryer LAT is 10 °C and that the shut-down setting is 25 °C. To modify
this setting, press the key "Modify" (F2):
Dryer LAT 10 °C
Warning Maximum 25 °C
Program Limits Cancel
F1 F2 F3
Fig. 8.15 Modify parameters menu
3. The key "Limits" (F2) can be used to find the limitations for the parameter. Use the or arrow
key to change the value.
4. Press the key "Program" (F1) to program the new setting or the key "Cancel" (F3) to cancel the
modification operation.
Note:
The modifying procedure for other settings is similar. For some settings, a delay can be
programmed. See section 8.15.
8.10 Modifying service plans
Function
To modify the hour intervals for the Service plans.
Service plans
The service operations to be carried out are grouped in plans, called Service plan A, B, D or I. When
reaching an interval, a message will appear on the screen indicating which Service plans are to be
carried out.