Grizzly G0501 Saw User Manual


 
-10- G0501 Sliding Table Saw
A fire may occur if your particular electrical
configuration does not comply with local
and state codes. The best way to ensure
compliance is to check with your local
municipality or a licensed electrician.
Your Shop Circuit Capacity
Always check to see if the wires in your circuit are
capable of handling the amperage draw from
your machine, as well as any other machines that
could be operating on the same circuit. If you are
unsure, consult a qualified electrician.
Figure 1b. Typical locking type L15-20 plug and
receptacle.
Serious personal injury could occur if you
connect your machine to the power source
before you have completed the setup
process. DO NOT connect the machine to
the power source until instructed to do so.
Wiring
The Model G0501 is prewired for 220V 3-phase
operation. If 440 voltage is required, rewire the
machine per the instructions on page 12 and fol-
low the circuit requirements on this page.
Amperage Draw
The Model G0501 has a 10 HP main motor and a
1 HP scoring motor that will draw the following
amps at 440V 3-phase :
Arbor Motor ........................................12.5 Amps
Scoring Motor ......................................1.5 Amps
Circuit Breaker Requirements
Install the machine on a dedicated circuit to
reduce the possibility of overloading the circuit
and tripping the circuit breaker. If the circuit
breaker trips and the circuit is of the correct load
capacity, have the circuit inspected by qualified
electrician. Never use a larger circuit breaker
than stated below, or you will increase the risk of
fire.
Circuit Breaker ............................20 Amp, 3 Pole
Minimum Cord Requirements
For 440V 3-phase operation, use the following
type of cord (a cord is not included):
Cord................................................3 pole, 4 wire
Gauge ..............................................................12
Plug Type
The plug you install on your cord will depend
upon the type of service you currently have or
plan to install. We recommend using the following
plug and receptacle for your machine on a dedi-
cated circuit only (see Figure 1b for an example):
Plug & Receptacle ..................................L15-20
440V 3-Phase